Most of the tooltypes can be set with options on the GUI. Facts will detect changes
made to its icon information and ask you if you want to reload the config.

DONOTWAIT
Set this. Keep it set. Only affects running FACTS from the WBStartUp
drawer, and Workbench'll moan if you don't.

STARTPRI
This tells WB the order in which to load programs in the WBStartUp drawer.
Please note that saving settings will overwrite this option,
so please instead ensure that RexxMast has a STARTPRI of more than 0 (or,
better, execute it in s:user-startup)

CXPRIORITY
FACTS's priority as a commodity. Probably safe to set this to something
ridiculously low.

CXPOPUP
Set this to "YES" if you want the GUI to appear on startup, and "NO" if you
don't. I would suggest setting it to "NO" if you put FACTS in WBStartUp,
and "YES" at all other times.

CXPOPKEY
Hotkey combination to pop up FACT's GUI. The default is "ctrl alt f", which
probably interferes with FKey's default. And FTPMount's, come to that.

CHECKKEY
Hotkey to synchronise the system time. See several ways to pay

TIMEOUT OBSOLETE
Specifies the timeout in seconds for receiving data - now specified in TIMESERVER

COMMAND
Sets a command to execute after sccessful sync.
(NB: this option has changed slightly in r4.91!)

STRATUM1DB and STRATUM2DB
Sets the path and filname of the local servers databases.
Defaults to PROGDIR:clock1.htm and PROGDIR:clock2.htm
Should be possible to set to eg. http://www.eecis.udel.edu/~mills/ntp/clock1.htm
to always consult the server copy of the database, if you have an http-handler installed.

DEBUG
Do NOT set this unless I tell you to, as strange things may
happen.

CUSTOM DST SETTINGS

DSTSTARTMONTH
Month when DST begins, from 1-12

DSTSTARTWDAY
Day of week when DST begins, 0=Sunday, 1=Monday etc

DSTSTARTHOUR
Time when DST starts (hours only). eg. 1 = 1:00am

DSTSTARTWEEK
Which week in the month DST begins. 0=last, 1=first, 2=second, etc

HEMISPHERE
Set to "NORTH" or "SOUTH". If AutoDST isn't working properly, then you've
set it wrong!

DSTENDMONTH
DSTENDWDAY
DSTENDHOUR
DSTENDWEEK

Specify when DST ends. See the DSTSTART tooltypes.


The following tooltypes can - and should - be set from the GUI!

WRITETO
Flags: BATTCLOCK, SYSTEM
Specify more than one option by using the "or" (vertical bar) operator.

TINT
Specify the time interval between automatic checks in seconds.

DSTNAME
Specify the name of your summertime. Please use four characters!

UTC OBSOLETE
Specifies whether to use UTC, Local or Other timezone.

AUTODST
Specify AutoDST mode: -1 = custom. Any other number is the option in the
AutoDST menu starting from 0 (off) at the top!

IGNORETZ
Set to stop the clock being adjusted along with the TZ env-var.

DAYTIMEPORT
Specifies the current TCP port to use for the 'daytime' service. Defaults
to 13

TIMEPORT
Specifies the current TCP port to use for the time/tcp service. Defaults to
37

SERVICE OBSOLETE
Specifies the current service.
123 = sntp, 13 = daytime, 37 - time/tcp, 372 = time/udp

UTCOFFSET
Specifies timeserver's offset from GMT as seconds east.

SNTPPORT
Specifies the current UDP port for the sntp service. Defaults to 123

UDPTIMEPORT
Specifies the current UDP port to use for the time/udp service. Defaults to
37

COMPATIBILITY
Flags option. Multiple options are separated by vertical bar.
Options: MODE2036 = 2036 mode
BASE2015 = use 2015 as two-digit base
BATT2078 = BattClock 2078 correction

APPMENU
If set, an AppMenu item will appear in the Workbench "Tools" menu.

EXTRAHALF
If set, an extra half-hour will be added to your whole hour TZ offset.

QUIETDST
If set, AutoDST will not notify you of the change
(this also applies to leap seconds - see OBSESSION)

STGEMUL
If set, SummerTimeGuard emulation will be enabled.

CHECKONSTARTUP
If set, FACTS will check for the current time on startup.

DEFPORT OBSOLETE
Specifies that the default port should be used, instead of the #?PORT
values above.

ALWAYSUPDATE
Specifies that the "Amiga" time on the GUI should continually update.

ANINC OBSOLETE
Enables Aninc auto server change system. See ONERROR.

ONERROR
Specifies what should be done if an error occurs.
ANINC and/or NEXTSERVICE.

OBSESSION
Will enable auto-adjustment of leap seconds at midnight.

WINX and WINY
Specifies the position of the GUI in pixels from the left (X) and top (Y).

ZOOMED
Specifies that the window should be minimised to the titlebar when opened.

DEFSERVER
Specifies which server Facts should use as the default (see also TIMESERVER
env-var)

TIMEENV
Specifies that Facts should write ENV:Facts/time once a minute.